XINKONG 9,000 LB L2910 2 POST LIFT CAR LIFT AUTO TRUCK H
- XINKONG
- COME WITH ADJUSTABLE PADS. TRUCK ADAPTERS ARE INCLUDED
- SAFETY MECHANISM:
- DOUBLE POINT SAFETY LOCK RELEASE
- AUTOMATIC ARM LOCK RESTRAINTS
- RELIEF VALVE BUILT-IN POWER PUMP TO PREVENT OVERLOADING
- DOOR GUARDS PROTECTION RUBBER
- UP-LIMIT SWITCH TO PROTECT CYLINDERS WORKING STROKE USED IN SAFE LENGTH SCOPE
- HEAVY DUTY 5/16″ DIAMETER CABLE AND 4.56″ PULLEY REDUCE HIGH STRESS ON SYNCHRONIZATION PROCESS AND INCREASE CABLE LIFE
- STIFFENED BASE PLATE 15/32″ THICKNESS
- ULTRA-HIGH MOLECULAR SELF-LUBRICATING NYLON SLIDER ENSURES CARRIAGE SMOOTH MOVING UP AND DOWN
- ANCHOR BOLTS/MOUNTING HARDWARE INCLUDED
CONTROL SYSTEM
- LIFTING OPERATION BY PRESSING “UP” BUTTON ON MOTOR
- MANUAL LOWERING OPERATION BY PRESSING LEVER
- RELIEF VALVE BUILT-IN POWER PUMP TO PREVENT OVERLOADING
- LIFTING CAPACITY: 9,000 LBS
- THE OVERALL HEIGHT 145 21/32″
- THE OVERALL WIDTH 133-1/4″
- COLUMN WIDTH 10.59″
DISTANCE BETWEEN 2 POST 106-5/16″
- Overall width 131-1/2″
- Base Width 14-9/16″
- Column Thickness of Steel 11/64″
- Carriage Thickness of Steel 3/16″
- Arms Thickness of Steel 15/64″
-
Front Arm 29.9″-47.2″
-
Rear Arm 29.9″-47.2″
-
Min pad height: 3-7/8″
-
Lift height max: 74-13/16
-
Drive-thru width clearance: 99-7/32″
-
Time to full rise: 55 sec
-
Shipping Weight: 1370 lbs
Site Selection
Before installing your auto lift, check the following:
Lift Location: Always use the architect’s plans when available. Check layout dimensions against floor plan requirements making sure adequate space is available. Your lift requires a 220v or 110v, 30amp, single-phase, grounded electrical source. There should be room enough to operate the lift in a safe manner and without restrictions.
Overhead Area: The area where the lift will be located should be free of overhead obstructions such as heaters, building supports, electrical lines, doors, lights, etc.
Floor Area: Visually inspect the site where the lift is to be installed and check for cracked or defective concrete.
Floor Requirements
A level floor is suggested for proper installation and level lifting. Small differences in floor slopes may be compensated for by proper shimming. If a floor is of questionable slope, consider a survey of the site and/or the possibility of pouring a new level concrete slab.
New concrete must be adequately cured for at least 30 days.
DO NOT install auto lift on any asphalt surface or any surface other than concrete.
DO NOT install auto lift on expansion seams or cracked or defective concrete.
DO NOT install an auto lift on a second/elevated floor without first consulting the building architect.
DO NOT install an auto lift outdoors unless special consideration has been made to protect the power unit from inclement weather conditions.
Concrete Specifications
All models MUST be installed on 3,000 PSI reinforced concrete only. Additional concrete requirements will vary by lift.
8,500 lbs – 10,000 lbs lifts: 4? Minimum Thickness
11,000 lbs – 15,000 lbs lifts: 6? Minimum Thickness